Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
Braz. dent. j ; 29(4): 342-346, July-Aug. 2018. graf
Article in English | LILACS | ID: biblio-974171

ABSTRACT

Abstract The aim of this is was evaluate the vertical and horizontal marginal adaptation of 3-unit fixed partial denture frameworks fabricated using different techniques and CAD/CAM systems. A total of 40 framework specimens were fabricated and divided into four groups as follows: lost-wax casting (G1); lost-wax casting with welding (G2); extraoral optical scanning of models (3S/DWOS) (G3); intraoral optical scanning (Cerec Bluecam/Sirona) (G4). A reference model was used to simulate a fixed partial denture with three elements (with a central pontic). The frameworks of G1 and G2 were cast in nickel-chromium (NiCr) alloy, whereas those of G3 and G4 were milled in zirconia. In all groups, vertical and horizontal marginal adaptation (over-contour and under-contour) was evaluated using a three-dimensional optical microscope (Quick Scope, Mitutoyo). The results showed higher vertical marginal misfit in G1 than in the other groups (p<0.001). Regarding horizontal marginal misfit, higher over-contour values occurred in G3 than in the other groups (p<0.001). G3 did not show under-contour at all, whereas the other groups did not differ from each other in this regard (p>0.05). Within the limitations of this study, it can be concluded that lost-wax casting with welding is a viable alternative to the use of CAD/CAM systems to fabricate frameworks of three-unit FPDs, since the techniques yielded similar vertical misfit values. Extra-oral CAD/CAM systems showed the highest horizontal misfit (over-contour) compared to other groups.


Resumo O objetivo deste estudo foi avaliar a adaptação marginal vertical e horizontal de infraestruturas de prótese fixas de três elementos confeccionadas por diferentes técnicas e diferentes sistemas CAD/CAM. Um total de 40 infraestruturas foram confeccionadas e divididas em quatro grupos: fundição por cera perdida (G1); fundição por cera perdida com ponto de solda (G2); escaneamento óptico extraoral para escaneamento do modelo (3S/DWOS); escaneamento óptico intraoral (Cerec Bluecam/Sirona) (G4). Uma matriz metálica foi utilizada para simular uma prótese fixa de três elementos (com pôntico central). As infraestruturas do G1 e G2 foram fundidas em liga metálica de níquel-cromo (NiCr), enquanto que as infraestruturas de G3 e G4 foram fresadas em zircônia. Todos os grupos foram analisados quanto à adaptação marginal vertical e horizontal (sobrecontorno e subcontorno) em microscópio óptico tridimensional (Quick Scope, Mitutoyo). Os resultados apresentaram maiores valores de desadaptação marginal vertical no G1 comparados aos outros grupos (p<0,001). Em relação a desadaptação marginal horizontal, maiores valores de sobrecontorno foram observado no G3 em comparação com os demais grupos (p<0,001). Não foi observado valores de subcontorno para o G3, enquanto que os demais grupos não apresentaram diferença significante para o subcontorno (p> 0,05). Dentro das limitações do presente estudo, pode-se concluir que a técnica convencional após ponto de solda é uma alternativa viável para confecção de infraestruturas de próteses fixas de três elementos comparado ao uso de sistemas CAD/CAM, uma vez que as técnicas apresentaram valores de adaptação marginal vertical similares. Os sistemas CAD/CAM extraoral apresentou o maior desajuste horizontal (sobrecontorno) em comparação com outros grupos.


Subject(s)
Humans , Dental Casting Technique , Denture Design/methods , Computer-Aided Design/instrumentation , Dental Marginal Adaptation , Denture, Partial, Fixed , Dental Materials , Models, Theoretical
2.
Araçatuba; s.n; 2017. 149 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-880365

ABSTRACT

Introdução: Os sistemas CAD-CAM tem sido responsáveis por automatizar a produção odontológica, otimizando o tempo e tornando este processo cada vez mais viável. Objetivo: O objetivo deste trabalho foi mensurar as desadaptações marginais vertical (DMV) e horizontal positiva (DMHP) e negativa (DMHN) de PPF de zircônia confeccionadas por diferentes sistemas CAD-CAM e por um método convencional, e analisar pelo MEF-3D (método dos elementos finitos tridimensionais) a influência das desadaptações no comportamento biomecânico das estruturas protéticas. Além disso, confeccionar uma revisão sistemática e meta-análise comparando os estudos da literatura que tenham avaliado a desadaptação marginal de próteses e componentes protéticos implantossuportados confeccionados pelos sistemas CAD-CAM e pelo método convencional da fundição por cera perdida. Materiais e Métodos: Quarenta infraestruturas (n=10) foram confeccionadas (G1: Cerec Bluecam, G2: iTero, G3: 3Series, G4: Ni-Cr), e randomizadas para mensuração das desadaptações. Os resultados encontrados foram submetidos à análise de variância (ANOVA), com nível de significância à 5%. Os valores médios de DMV de cada grupo foram utilizados para a confecção de 6 modelos pelo MEF-3D, submetidos à aplicação de forças axiais e oblíquas. Os resultados foram visualizados através de mapas de tensão Von Mises. A revisão sistemática foi desenvolvida de acordo com o PRISMA e registrada na plataforma PROSPERO (CRD42017055685). Resultados: Os resultados do capítulo 1 foram: o método convencional apresentou menores valores de desadaptação vertical do que os sistemas CADCAM (p<0.05). Os sistemas CAD-CAM apresentaram menores valores de DMHN (p=0.014) e o método convencional não apresentou valores de DMHP. Na análise biomecânica, o carregamento oblíquo concentrou uma maior quantidade de tensões do que o carregamento axial, em todas as situações avaliadas. Os modelos adaptados apresentaram comportamento biomecânico mais favorável do que os modelos desadaptados, enquanto pequenas variações de desadaptações não influenciaram de maneira significativa no padrão de distribuição de tensões entre os modelos analisados. O parafuso protético foi a estrutura que concentrou a maior quantidade de tensões. Os resultados do capítulo 2 foram: 12 estudos elegíveis e publicados de 2011 a 2017, avaliados qualitativamente e quantitativamente por meio da realização de uma meta-análise. Na análise geral os sistemas CAD-CAM apresentaram menores valores de desadaptação do que o método convencional (p< 0.03). Para as próteses unitárias (p<0.00001) e parafusadas (p=0.01) os sistemas CAD-CAM também foram superiores ao método conveniconal. Conclusões: 1) O método de confecção utilizado influenciou as adaptações das infraestruturas, tanto para as medidas verticais quanto para as medidas horizontais, sendo o método convencional o mais preciso e o Sistema Cerec Bluecam o menos favorável; 2) A desadaptação influenciou na distribuição das tensões nas estruturas protéticas, sendo as próteses adaptadas mais favoráveis biomecanicamente do que as próteses desadaptadas; 3) A partir da meta-análise pode-se concluir que os sistemas CAD-CAM foram mais favoráveis do que o método convencional na confecção de restaurações implantossuportadas unitárias e parafusadas(AU)


Background: CAD-CAM systems in dentistry automate production, thus optimizing time and making the process even more convenient. Purpose: The aim of this study was to measure vertical (VMD) and positive (PHMD) and negative horizontal (NHMD) marginal discrepancy of FPD frameworks made by different CAD-CAM systems (zirconia Y-TZP) and conventional method (cast), and to analyze by FEA-3D the biomechanical performance of implant-prosthesis misfit. In addition, to do a systematic review and meta-analysis comparing studies in the literature that have evaluated the marginal misfit of prostheses and implantsupported prosthetic components made by the CAD-CAM systems and the conventional method of lost-wax casting. Material and Methods: Forty frameworks (n=10) were fabricated (G1: Cerec Bluecam, G2: iTero, G3: 3Series, G4: Ni-Cr) and were randomized, to measure the misfits. The results were submitted to analysis of variance (ANOVA), with significance level at 5%. The average values of DMV of each group were used to make six models using FEA-3D, applying axial and oblique loads. The results were analyzed using maps of Von Mises stresses, for each model. The systematic review was developed according to PRISMA statement and was register in the PROSPERO (International prospective register of systematic reviews) (CRD42017055685). Results: The results of chapter 1 were: the conventional method showing the lowest values of vertical misfit compared to CAD-CAM systems (p<0.05). The CAD-CAM systems showing lowest values of PHMD (p=0.014) and the conventional method did not present values of NHMD. In the biomechanical analysis, the oblique loading concentrated a greater amount of stresses than the axial loading, in all situations evaluated. The fit models presented the most favorable biomechanical performance compared to misfit models and slight variations in misfit values did not influence significantly the pattern of stress distribution between the analyzed models. The screw was the prosthetic component that concentrated the highest amount of stresses. The results of chapter 2 were: 12 eligible studies published between 2011 and 2017, qualitative and quantitative evaluated by the meta-analysis. In general analysis the CAD-CAM systems presented the lowest values compared to conventional method (p<0.03). For the single-unit (p<0.00001) and screwed (p=0.01) implant-supported prosthesis the CAD-CAM systems were also superior to conventional method. Conclusions: 1) The marginal vertical and horizontal misfit were influenced by the frameworks manufacturing technique, being the conventional method the most favorable and the Cerec Bluecam system the less favorable; 2) The marginal misfit was more damaging to stress distribution in the implant-prosthesis, with the fit models being more favorable than the misfit ones and the variations of the misfit between the groups were not significant in the stress generated in the implant-supported components; 3) From the metaanalysis it can be concluded that the CAD-CAM systems were more favorable than conventional method to fabricate single-unit and screwed implant-supported prosthesis(AU)


Subject(s)
Biomechanical Phenomena , Dental Implants , Dental Prosthesis , Computer-Aided Design , Dental Marginal Adaptation , Dental Prosthesis, Implant-Supported , Finite Element Analysis
3.
Prosthes. Lab. Sci ; 5(20): 60-69, jul.-set. 2016. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-848103

ABSTRACT

O objetivo deste trabalho foi relatar um caso clínico de reabilitação oral utilizando diferentes materiais estéticos em tratamento reabilitador, envolvendo implante dentário e restaurações metal free na região maxilar anterior. Paciente M.S.S. compareceu à clínica de reabilitação com queixa estética da região anterior e desconforto por uso de aparelho móvel. Primeiramente, foi solicitada tomografia da região, que mostrou tecido ósseo suficiente para implantação. Após criterioso exame clínico, foi planejado confecção de coroas estéticas nos elementos 13 a 23, sendo uma coroa implantossuportada no dente 22. Uma vez aceito o tratamento pela paciente, este se iniciou através do enceramento diagnóstico para planejamento estético e confecção de guias para auxiliar no controle do desgaste dentário e confecção dos provisórios. Inicialmente foi instalado um implante cone morse (3,5 x 13 mm) na região do dente 22, aguardando-se 6 meses para sua osseointegração. Após esse período, foram removidas coroas protéticas antigas e confeccionados núcleos de fibra de vidro nos dentes 11 e 21 e de preenchimento com pino intradentinário no dente 12. Posteriormente foram realizados os preparos dentários e moldagem pela técnica do duplo fio. Para os elementos 13, 12, 11, 23 e 24 foram confeccionadas restaurações de dissilicato de lítio (sistema IPS e.max) e para o 22 coroa implantossuportada em zircônia (sistema IPS e.max). Após prova e cimentação das coroas, o caso foi finalizado e pode-se observar harmonia estética na região anterior maxilar, além de uma ótima saúde periodontal.


The aim of this study was to describe a case report of oral rehabilitation using different aesthetic materials for oral rehabilitation involving implant and metal-free restorations in the anterior maxillary region. Patient M.S.S. attended the rehabilitation clinic with aesthetic complaint of poor aesthetic in the anterior region and discomfort due to the use of remov-able appliance. A CT scan was requested and showed sufficient bone tissue for implantation. Thus, after careful clinical examination it was planned fabrication of aesthetic single crowns on #13 to #23 teeth being an implant-supported crown on tooth #22. With patient's consent the rehabilitation started with planning through diagnostic wax-up for aesthetic planning and fabrication of guides to assist in the control of dental preparation and fabrication of provisional crowns. Initially, a morse taper implant (3.5x13 mm) was installed in region of tooth #22, waiting for osseointegration for 6 months. Then old crowns were removed and glass fiber posts were installed in the #11 and #21 teeth as well as a core build-up with mini screw metallic pin in the #12 tooth. Subsequently dental preparations and impression were performed using the double retraction cord technique. Lithium disilicate (IPS e.max) restorations were manufactured for elements #13, #12, #11, #23 and #24 while for #22 it was made a zirconia implant-supported crown (IPS e.max). After prove and cementation of crowns, the case was finalized resulting on good aesthetics and periodontal health in the anterior maxillary region.


Subject(s)
Humans , Female , Adult , Dental Prosthesis, Implant-Supported , Denture, Partial, Fixed , Esthetics, Dental , Mouth Rehabilitation , Post and Core Technique , Tomography, X-Ray Computed
4.
Prosthes. Lab. Sci ; 5(20): 107-111, jul.-set. 2016. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-848111

ABSTRACT

Para a reabilitação de espaços edêntulos, o tratamento de escolha na maioria dos casos é a reabilitação com implantes, mas nem sempre é possível executar esse tratamento devido às limitações anatômicas como, por exemplo, a reabsorção óssea que pode ocorrer após a extração dos dentes. Isso leva à utilização de técnicas de enxerto ósseo, sendo que nesse procedimento podem ser utilizados osso autógeno, biomateriais ou a associação de ambos. Os avanços clínicos, com a utilização de substitutos ósseos alógenos, xenógenos e aloplásticos, levam a considerar essas opções como válidas para o processo de reparo tecidual, devido à ausência de reabsorção em volume, ao sítio cirúrgico unitário e ao melhor pós-operatório. Visando acelerar a neoformação óssea, tem sido pesquisada a influência de células sanguíneas em biomateriais aplicados no corpo humano, como o de plasma rico em plaquetas (PRP), seguido da segunda geração de agregados de plaquetas, fibrina rica em plaquetas (PRFf). O PRF é constituído em medula óssea de megacariócitos (grande núcleo celular), plaquetas são estruturas discoidais e anucleares. Tem uma vida útil de 8 a 10 dias e o citoplasma contém muitos grânulos, cujos conteúdos são secretados no momento da ativação, α-grânulos contêm muitas proteínas, específicas de plaquetas ou não específicas de plaquetas. Contudo, desgranulação também implica a liberação de citocinas capazes de estimular a migração e proliferação de células no interior da matriz de fibrina, lançando as primeiras fases de cicatrização.


For rehabilitation of edentulous spaces rehabilitation, the treatment of choice in most cases is the rehabilitation with dental implants. however that approach is not always possible to perform due to anatomical limitations such as bone reabsorption after tooth extraction. Such cases require bone grafting techniques that may be performed using autogenous bone, biomaterials or a combination of both. Clinical improvements with the use of allogeneic, xenogenous and alloplastic bone substitutes indicate that those are valid options for the tissue repair process due to lack of volume reabsorption, the surgical site unit and the best postoperative results. To accelerate bone formation, it has been investigated the influence of blood cells on biomaterials applied to the human body, such as platelet-rich plasma (PRP), followed by the second generation of platelet aggregates, platelet-rich fibrin (PRF). The PRF consists of megakaryocytes bone marrow (large cell nucleus), platelets are discoidal and anuclear structures. It has a life span of 8 to 10 days, and the cytoplasm contains many granules which contents are secreted at the time of activation, α-granules contain many specific or non specific platelets proteins. however, degranulation also the releases of involves which are able to stimulate the migration and proliferation of cells within the fibrin matrix, releasing the early stages of cicatrization.


Subject(s)
Humans , Female , Middle Aged , Biocompatible Materials/therapeutic use , Bone Regeneration , Bone Transplantation/statistics & numerical data , Fibrin , Sinus Floor Augmentation
5.
Prosthes. Lab. Sci ; 5(20): 70-77, jul.-set. 2016. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-859394

ABSTRACT

A aplicação dos conceitos da Odontologia Estética nos procedimentos protéticos tornou-se rotina para profissionais que realizam grandes reabilitações orais e isso ocorreu, em grande parte, devido à evolução das cerâmicas odontológicas e sua adesão ao substrato, bem como o desenvolvimento de novas técnicas protéticas e novos equipamentos. Essas tecnologias permitiram a otimização do tempo clínico e possibilitaram a finalização de casos complexos em intervalo de tempo bem curto. Assim, o objetivo deste artigo foi relatar um caso clínico de correção estética utilizando coroas livre de metal que gerou melhoria da autoestima do paciente idoso, muito em virtude do curto tempo de tratamento. Paciente do sexo masculino, 62 anos, compareceu à clínica de reabilitação da FOA-UNESP queixando-se de problemas estéticos e demonstrando interesse em reabilitação oral da arcada superior. Na fase de anamnese, o paciente relatou ter depressão severa, não apresentando motivação suficiente para a execução do tratamento; porém, ele aceitou a proposta planejada quando estava acompanhado dos familiares. Coroas livres de metal foram planejadas para a resolução do caso, que também foi associado à confecção de um elemento unitário sobre implante. Por fim, o tratamento proposto foi capaz de corrigir os problemas estéticos identificados inicialmente, promovendo melhoria expressiva na autoestima do paciente, que inclusive se mostrou motivado para complementar o tratamento das demais áreas não contempladas no planejamento inicial.


The application of the cosmetic dentistry concepts in prosthetic procedures has become a routine for professionals who perform oral rehabilitation. That occurred mostly due to the improvement of dental ceramics and their bonding to dental substrate, as well as to the development of new prosthetic techniques and new equipment. These technologies allowed the optimization of clinical time and enabled the completion of complex cases in a very short time. Thus, the aim of this article was to report a case of aesthetic correction using metal free crowns that improved the self-esteem of an elderly patient mostly because of the very short treatment time. A 62-year-old man presented to the oral rehabilitation clinic of FOA-UNESP complaining about aesthetic problems and showing interest in oral rehabilitation of the upper arch. In the anamnesis phase, the patient reported having severe depression, no sufficient motivation for the implementation of treatment; however, he accepted the planned proposal when accompanied by family. Metal free crowns were planned for the resolution of the case, which was also associated with a single element on the implant. finally, the proposed treatment was able to correct the identified aesthetic problems promoting significant improvement of patient's self-esteem who was also motivated to complement the treatment including other areas that were not included in the initial planning.


Subject(s)
Humans , Male , Middle Aged , Computer-Aided Design , Dental Prosthesis , Denture, Partial, Fixed , Esthetics, Dental , Resin Cements , Zirconium
6.
Rev. odontol. UNESP (Online) ; 44(5): 262-267, set.-out. 2015. tab
Article in English | LILACS, BBO | ID: lil-763343

ABSTRACT

Introduction: Temporary restorative materials are widely used, however, little is know about their color stability. Objective: to evaluate the color stability of the following temporary restorative materials: acrylic and bis-acrylic resins after immersion in pigmenting solutions for different periods of storage. Material and method: Four materials were tested (Dêncor/Clássico, Protemp 4/3M ESPE; Structur 2 SC/Voco; Luxatemp AM Plus/DMG) and 30 test specimens (15 mm in diameter and 2 mm thick) per material were fabricated. They were divided according to the storage medium (artificial saliva, saliva + cola type soda, and saliva + coffee) and storage time intervals (2, 5, 7 and 15 days). Color measurements were made before and after immersions, with use of a spectrophotometer, by means of the CIE L*a*b* system. The data were analyzed by the analysis of variance and the Tukey Test, at a level of significance of 5%. Result: Acrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). When bis-acrylic resins were compared no significant difference was observed between the resins Structur and Luxatemp (p=0.767). As regards solutions tested, coffee showed the highest color change values (p<0.001), and the longer the storage time interval, the greater was the color change in all the temporaryrestorative materials analyzed (p<0.001). Conclusion: Acrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001). Coffee caused the greatest color change, and immersion time was determinant in color stability of the temporary materials analyzed.


Introdução: Os materiais restauradores provisórios são amplamente utilizados, porém pouco se sabe a respeito de sua estabilidade de cor. Objetivo: Avaliar a estabilidade de cor de materiais restauradores provisórios: resina acrílica e resinas bisacrílicas, após a imersão em soluções pigmentantes, durante diferentes períodos de armazenamento. Material e método: Quatro materiais foram testados (Dêncor/Clássico, Protemp 4/3M ESPE; Structur 2 SC/Voco; Luxatemp AM Plus/DMG) sendo confeccionadas 30 amostras (15 mm de diâmetro e 2 mm de espessura) por material. Estes foram divididos de acordo com o meio de imersão (saliva artificial, saliva + refrigerante tipo cola e saliva + café) e período de armazenamento (2, 5, 7 e 15 dias). As mensurações de cor foram realizadas antes e após as imersões, com auxílio de um espectrofotômetro, através do sistema CIE L*a*b*. Os dados foram analisados com análise de variância (ANOVA) e Tukey, com nível de significância à 5%. Resultado: A resina acrílica apresentou maior estabilidade de cor quando comparada às resinas bisacrílicas (p<0,001). Comparando as resinas bisacrílicas, não foi observado diferença significativa entre as resinas Structur e Luxatemp (p=0,767). Em relação as soluções testadas, o café apresentou os maiores valores de alteração de cor (p<0,001), sendo que quanto maior o período de armazenamento, maior foi a alteração de cor de todos os materiais provisórios analisados (p<0,001). Conclusão: A resina acrílica apresentou maior estabilidade de cor, quando comparada às bisacrílicas. O café causou a maior alteração de cor, e o tempo de imersão foi determinante na estabilidade de cor dos materiais provisórios analisados.


Subject(s)
Spectrophotometers , Analysis of Variance , Dental Prosthesis , Color , Dental Restoration, Temporary , Acrylic Resins , Coffee
7.
Full dent. sci ; 6(21): 82-88, dez. 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-750186

ABSTRACT

Algumas vezes nos deparamos no consult¢rio com situa‡ães cl¡nicas, nas quais a falta de harmonia no sorriso encontra-se devido a uma grande exposi‡Æo de tecido gengival. Nestes casos o profissional deve ser capaz de realizar uma an lise detalhada dos componentes est ticos e dinƒmicos do sorriso, em busca de um planejamento e tratamento satisfat¢rios, que poder  englobar diferentes especialidades odontol¢gicas. Para estas situa‡ães, a associa‡Æo periodontia/pr¢tese ‚ uma alternativa vi vel a ser proposta ao paciente, que vem sendo utilizada de maneira positiva em busca de uma condi‡Æo est‚tica e funcional favor vel ao paciente, sem deixar de lado os princ¡pios de preserva‡Æo dos tecidos periodontais e da estrutura dent ria remanescente. Diante disso, o objetivo deste trabalho foi descrever um caso cl¡nico no qual a associa‡Æo periodontia/pr¢tese foi proposta para corre‡Æo de sorriso gengival e vestibulariza‡Æo dent ria. Atrav‚s do resultado cl¡nico obtido e a satisfa‡Æo do paciente, podemos entender que o tratamento multidisciplinar envolvendo a associa‡Æo de t‚cnicas periodontais e prot‚ticas em casos com comprometimento est‚tico gengival e dental, ‚ favor vel para alcan‡ar um resultado positivo.


Sometimes we face clinical situations in which the lack of harmony in the smile is caused by a major exhibition of the gingival tissue. In these cases the professional should be able to perform a detailed analysis of the static and dynamic components of the smile, in search of a satisfactory planning and treatment which may include different dental specialties. For these situations, the association of periodontics/prosthesis is a viable alternative that has been used positively in search of an aesthetic and functional condition that benefits the patient, without leaving aside the preservation of periodontal tissues and of the remaining structure of the tooth. Thus, the aim of this study was to describe a case in which the association between these two areas was proposed to correct gummy smile and dental vestibularization. Clinical results and the satisfaction of the patient indicate that this multidisciplinary treatment combining periodontal and prosthetic techniques is favorable to positive results in cases of compromised smile aesthetics due to excessive gum tissue.


Subject(s)
Humans , Female , Adult , Ceramics/therapeutic use , Periodontal Diseases/therapy , Dental Veneers , Gingivoplasty , Patient Satisfaction , Smiling/psychology , Patient Care Planning , Dental Prosthesis , Surgical Procedures, Operative
8.
In. Miyashita, Eduardo; Pellizzer, Eduardo Piza; Kimpara, Estevão Tomomitsu. Reabilitação oral contemporânea baseada em evidências científicas. Nova Odessa, Napoleão editora, jun. 2014. p.212-271, ilus. (BR).
Monography in Portuguese | LILACS, BBO | ID: lil-715168
9.
Full dent. sci ; 5(17): 67-75, jan. 2014. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-706298

ABSTRACT

A procura por uma estética imediata durante a instalação de implantes em regiães anteriores tem sido observada gradualmente na Implantodontia, sendo assim, o cirurgião dentista deve estar habilitado para oferecer ao paciente a melhor opção de tratamento não apenas em termos funcionais, mas também em termos estéticos. Desta forma, a literatura tem sugerido o uso de implantes de conexão do tipo Cone Morse para a resolução de situações clínicas que envolvam regiões anteriores. Assim, a proposta deste estudo foi apresentar um caso clínico e sugerir as particularidades de um planejamento de estética imediata com implante de conexão do tipo Cone Morse instalado na região anterior da maxila. Paciente de 21 anos, do gênero masculino, foi diagnosticado com fratura horizontal ao nível cervical do elemento dentário 11 e submetido … cirurgia de extração, seguida da instalação do implante osseointegrável modelo Flash© (Conexão, Sistemas de Implantes, Arujá, Brasil) com dimensães de 4,3 x 13 mm e geometria de conexão do tipo de Cone Morse. Após os procedimentos cirúrgicos foi realizada a personalização da própria coroa remanescente para instalação imediata como provisório. O procedimento de estética imediata com implantes osseointegráveis empregando o remanescente dentário do paciente ‚ uma técnica eficaz de reabilitação


Patients often search for an immediate aesthetic result on the anterior region during implant placement. Therefore, the dentist should be able to offer the best treatment option in both aesthetic and functional terms. Literature has suggested the use of implants of the type Morse Taper connections to the resolution of clinical situations involving anterior regions. The aim of this study was to introduce a clinical case and suggest a specific immediate aesthetic planning using a Morse Taper connection implant installed in the anterior maxilla. A 21-year-old male with horizontal fracture at the cervical level of the tooth 11 was submitted to surgical extraction, followed by the placement of the implant model osseointegrated Flash© (Conexão, Sistemas de Implantes, Aruj , Brazil) sizes of 4.3 x 13 mm and Morse Taper connection. After surgical procedures the remaining crown was customized for immediate installation as a provisional. The procedure with immediate aesthetic using osseointegrated implants and patients’ coronal remainder is an effective rehabilitation technique


Subject(s)
Humans , Male , Young Adult , Alveolar Ridge Augmentation , Esthetics, Dental , Tooth Extraction/methods , Tooth Extraction , Dental Implantation , Patient Satisfaction , Dental Prosthesis Design/methods , Biomechanical Phenomena , Radiography, Dental/methods , Radiography, Dental
10.
Araçatuba; s.n; 2014. 87 p. tab, graf, ilus.
Thesis in Portuguese | LILACS | ID: lil-755425

ABSTRACT

O objetivo deste estudo foi avaliar a adaptação marginal de infraestruturas de próteses fixas confeccionadas pelo Sistema CAD/CAM com três diferentes sistemas de aquisição de dados. Material e Métodos: Confeccionaram-se 50 corpos de prova; Convencional (Ni-Cr) (n = 10), GI: iTero (n = 10), GII: CerecBluecam/fresadora industrial (n = 10), GIII: 3S (n = 10) e GIV: CerecBlueCam/Sirona (n = 10). Os corpos de prova foram numerados e randomizados, realizou-se análise da desadaptação marginal vertical. Resultados: A análise intra observador indicou que não houve diferença estatisticamente significante (teste t pareado, p = 0.822) no período antes e depois das análises. O sistema convencional (321 μm) apresentou maior desadaptação quando comparado com o sistema CAD/CAM (89 μm) (p<0.001). O sistema intra oral (iTero) apresentou menor índice de desadaptação marginal, quando comparado com o sistema extra oral (3S), (p<0.001). O sistema aberto apresentou maior índice de desadaptação marginal (114 μm) quando comparado com intra oral (iTero), sendo p<0.001. Além disto, no sistema convencional, observou-se que os pré-molares apresentaram índice de desadaptação maior quando comparado (361 μm) com o molar (283 μm) (p<0.001), porém no sistema CAD/CAM não houve diferença estatisticamente significante na comparação de dentes pré-molares (93,7 μm) e molares (84,9 μm). Significância: O sistema CAD/CAM pode atuar mais favoravelmente, reduzindo o índice de desadaptação marginal, quando comparado com o sistema convencional de confecção de próteses dentárias. O sistema intra oral (iTero) comportou-se melhor quando comparado com os demais sistemas...


The aim of this study was to evaluate the marginal fit of frameworks produced by CAD/CAM systems with three different data acquisition. Material and Methods: We fabricated 50 frameworks: conventional (Ni-Cr) (n = 10), GI:iTero (n = 10), GII:CerecBluecam/industrial milling (n = 10), GIII:3S (n = 10), and GIV:CerecBlueCam/Sirona (n = 10). We numbered the specimens and analyzed them randomly. Results: Intra-observer analysis indicated no statistically significant difference (paired t-test, p = 0.822) before and after the analysis. The conventional system (321 μm) showed greater misfit than the CAD/CAM (89 μm) (p<0.001) system. The intraoral system (iTero) showed a lower rate of marginal misfit than the extra-oral system (3S), (p<0.001). The open system presented a higher marginal discrepancy (114 μm) than intraoral (iTero), with p<0.001. Moreover, in the conventional system, premolars (361 μm) showed a higher index of misfit than molars (283 μm) (p<0.001), but for the CAD/CAM system, there was no statistically significant difference between premolars (93.7 μm) and molars (84.9 μm). Significance: The CAD/CAM system can to act more favorably reducing the rate of marginal discrepancy than the conventional impression system of dental prosthesis. The intra oral system (iTero) was better than other systems...


Subject(s)
Humans , Computer-Aided Design , Dental Marginal Adaptation , Dental Prosthesis , Denture, Partial, Fixed
11.
Braz. dent. j ; 24(6): 635-641, Nov-Dec/2013. tab, graf
Article in English | LILACS | ID: lil-697668

ABSTRACT

The purpose of this study was to assess the influence of the crown height of external hexagon implants on the displacement and distribution of stress to the implant/bone system, using the three-dimensional finite element method. The InVesalius and Rhinoceros 4.0 softwares were used to generate the bone model by computed tomography. Each model was composed of a bone block with one implant (3.75x10.0 mm) with external hexagon connections and crowns with 10 mm, 12.5 mm and 15 mm in height. A 200 N axial and a 100 N oblique (45°) load were applied. The models were solved by the NeiNastran 9.0 and Femap 10.0 softwares to obtain the results that were visualized by maps of displacement, von Mises stress (crown/implant) and maximum principal stress (bone). The crown height under axial load did not influence the stress displacement and concentration, while the oblique loading increased these factors. The highest stress was observed in the neck of the implant screw on the side opposite to the loading. This stress was also transferred to the crown/platform/bone interface. The results of this study suggest that the increase in crown height enhanced stress concentration at the implant/bone tissue and increased displacement in the bone tissue, mainly under oblique loading.


A proposta deste estudo foi avaliar a influência da altura da coroa de implantes de hexágono externo sobre o deslocamento e distribuição de tensões para o sistema implante/osso utilizando o método de elementos finitos. Os softwares InVesalius e Rhinoceros 4.0 foram usados para gerar o modelo de osso por meio de uma tomografia computadorizada. Cada modelo foi composto de um bloco ósseo com um implante (3.75 x 10.0 mm) com conexão de hexágono externo e coroas de 10 mm, 12.5mm e 15 mm em altura. Uma carga axial de 200 N e oblíqua (45°) de 100 N foram aplicadas. Os modelos foram resolvidos pelo software NeiNastram 9.0 e Femap 10.0 para obtenção dos resultados que foram visualizados por meio de mapas de deslocamento, de von Mises (coroa/implante) e tensão máxima principal (osso). A altura da coroa sob carga axial não influenciou o deslocamento e concentração de tensões, enquanto que a carga oblíqua aumentou a ação destes fatores. A maior concentração de tensões foi observada no pescoço do parafuso do implante no lado oposto à aplicação de carga. Esta tensão foi transferida para a interface coroa/plataforma/interface óssea. Os resultados deste estudo sugerem que o aumento da coroa amplia a concentração de tensões no tecido ósseo/implante, aumentando o deslocamento no tecido ósseo, principalmente sob carga oblíqua.


Subject(s)
Crowns , Dental Implants , Models, Dental , Dental Prosthesis, Implant-Supported , Dental Prosthesis Retention/instrumentation , Dental Stress Analysis/methods , Biomechanical Phenomena , Dental Alloys , Dental Prosthesis Design , Finite Element Analysis , Software , Tomography, X-Ray Computed
12.
Rev. cir. traumatol. buco-maxilo-fac ; 13(3): 87-94, Jul.-Set. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-792287

ABSTRACT

A utilização dos implantes de maior comprimento pode ser mais favorável para a previsibilidade dos implantes dentários. Essa afirmação é pertinente, uma vez que a causa dos fracassos em implantes osseointegrados está mais relacionada às complicações biomecânicas. Assim, o objetivo deste estudo foi avaliar a influência da ampliação do comprimento ao redor da superfície do implante. Seis modelos foram criados com a presença apenas de um implante (Conexão Master Screw, Sistemas de Próteses, São Paulo, Brasil) do tipo hexágono externo de 3.75 mm x 7.0 mm (Modelo A), 3.75 mm x 8,5 mm (Modelo B), 3.75 mm x 10.0 mm (Modelo C), 3.75 mm x 11.5 mm (Modelo D), 3.75 mm x 13 mm (Modelo E), 3.75 mm x 15 mm (Modelo F) utilizando a metodologia de fotoelasticidade. Os resultados foram visualizados através de uma análise qualitativa de tensões (número e intensidade de franjas). O modelo A apresentou um padrão de distribuição de tensões menos favorável; o carregamento oblíquo foi o mais prejudicial para as estruturas relacionadas. Conclusão: O aumento do comprimento permitiu uma melhor distribuição de tensões. O carregamento oblíquo foi o mais prejudicial, quando comparado com o carregamento axial.


The use of implants of greater length may be more favorable for the predictability of dental implants. This statement is relevant, since the cause of failures in dental implants are more related to biomechanical complications. The aim of this study was to evaluate the influence of increase of the length around the entire body of the implant. Six models were created with the presence of only one hexagonal implant (Master Screw connection, Implant Systems, São Paulo, Brazil) of 3.75 mm x 7.0 mm (Model A), 3.75 mm x 8.5 mm (Model B ), 3.75 mm x 10.0 mm (Model C) 3.75 mm x 11.5 mm (Model D) 3.75 mm x 13.0 mm (Model E) 3.75 mm x 15.0 mm (Model F) using the method of photoelasticity. The results were visualized through a qualitative analysis of stresses (number and intensity photoelastic fringes). The model A showed a pattern of less favorable stress distribution, the oblique loading was the most detrimental to the related structures. Conclusion: The increased length allowed for a better distribution of stresses. The oblique loading was more detrimental when compared to axial loading.

13.
Odontol. clín.-cient ; 12(3): 231-235, Jul.-Set. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-778255

ABSTRACT

Fatores biomecânicos estão relacionados com a perda de implantes osseointegráveis, e, assim, uma análise rigorosa na seleção do melhor material oclusal para dissipação de tensões é necessária. Dessa forma, o objetivo deste estudo foi avaliar a influência de diferentes materiais oclusais no sistema coroa-implante, com destaque para o parafuso da coroa. Para isso, quatro modelos tridimensionais foram criados com um implante (Conexão Master Screw, Sistemas de Próteses, São Paulo, Brasil) do tipo hexágono externo de 3.75 mm x 10 mm com as seguintes coroas: NiCr, metalo-cerâmica (porcelana), resina composta e resina acrílica. Os resultados foram visualizados através dos mapas de tensão von Mises de cada modelo proposto. Os diferentes modelos analisados apresentaram um padrão de distribuição de tensões semelhantes. Assim, concluiu-se que os diferentes materiais oclusais foram semelhantes entre si, na coroa e no parafuso. O carregamento oblíquo foi o mais prejudicial quando comparado com o carregamento axial.


Biomechanical factors are related to the loss of dental implants, and a rigorous analysis in selecting the best material for occlusal stress distribution is required. In addition, it was suggested that occlusion material can also influence the distribution of stresses. The aim of this study was to evaluate the influence of different occlusal materials on the crown-implant system, especially the screw crown. Thus, four dimensional models were created with a hexagonal implant (Master Screw connection, Implant Systems, São Paulo, Brazil) of 3.75 mm x 10 mm with the following crowns: NiCr, metal-ceramic (porcelain) resin and composite acrylic resin. The results were visualized through von Mises stress maps of each model. The different models analyzed showed a pattern of similar tensions distribution. Thus, it was concluded that the different occlusal materials were similar among themselves regarding the crown and screw. The oblique loading was more detrimental when compared to axial loading.

14.
Full dent. sci ; 4(13): 186-194, out.-dez. 2012. ilus
Article in Portuguese | LILACS, BBO | ID: lil-681691

ABSTRACT

O escurecimento dental de origem medicamentosa pela ingestão da tetraciclina repercute negativamente na aparência do sorriso. A tetraciclina quando utilizada no período em que os dentes estão sendo formados pode induzir a formação de manchas de coloração amarelada ou marrom-acinzentada na estrutura dentária. Seu uso quando os dentes já estão formados ou erupcionados na cavidade bucal não provoca alterações perceptíveis nos elementos dentários. Os tratamentos indicados para essa ocorrência contemplam a microabrasão, clareamento e laminados. Este trabalho teve como objetivo apresentar os cuidados para o planejamento estético em casos de manchamentos dentários por tetraciclina, e a descrição clínica para execução de laminados cerâmicos confeccionados em IPS E-max (Ivoclar - Vivadent). A harmonia e estética obtidas na conclusão do caso traduzem a saúde e conforto devolvidos ao paciente para o tratamento proposto


The darkening of teeth caused by tetracycline ingestion affects the appearance of the smile in an undesirable way. When used during teeth formation period tetracycline can induce the appearance of yellow or grayish-brown stains in the dental structure. Its use does not cause noticeable changes in the teeth when the teeth are already formed or erupted in the oral cavity. In these cases recommended treatments includes micro abrasion, tooth whitening and ceramic veneers. This paper aimed at presenting aspects that must be observed on aesthetic planning on cases of dental staining caused by tetracycline, as well as describe clinical steps for the execution of ceramic laminates produced using IPS E-max (Ivoclar -Vivadent). Harmony and aesthetics results obtained after the treatment are reflected on the restoration of patient’s health and comfort


Subject(s)
Humans , Female , Adult , Dental Cements/chemistry , Esthetics, Dental , Dental Veneers , Computer-Aided Design , Tetracycline/administration & dosage
15.
Clín. int. j. braz. dent ; 8(3): 310-322, jul.-set. 2012. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-716634

ABSTRACT

O avanço no campo da tecnologia adesiva e dos materiais indiretos se reflete no aumento da aplicação das restaurações indiretas adesivas que utilizam a resina laboratorial indireta (cerômero), permitindo ao clínico alcançar resultados funcionais e estéticos satisfatórios. Este trabalho apresenta os detalhes técnicos para a realização de inlays de resina laboratorial indireta nos dentes posteriores, enfatizando a técnica de selamento dental imediato ou pré-hibridização, ilustrando as etapas clínicas para se obter sucesso longitudinal


Advances of the adhesive technology and indirect materials resulted in the increased use of indirect restorations. The use of adhesive indirect resins (ceromers), allows the dentistry to achieve satisfactory functional and esthetic results. This paper presents the technical details to produce indirect resin inlay-type restorations, emphasizing the technique of immediate dental sealing or pre-hybridization, illustrating the steps to achieve clinical long-term success


Subject(s)
Humans , Male , Adult , Dental Materials , Esthetics, Dental , Inlays , Resins, Synthetic
SELECTION OF CITATIONS
SEARCH DETAIL